| Important points for operating
|
When the turbo type blower is in operation,
its pressure has an inverse ratio to the current. If the current is too
high, the contactor will trip. In order to avoid tripping or for saving
power, when the pipe is very short, or the resistance is very less,
please use wind regulating disc. The total section area of the air hole
should be less than 70% of the section area of the blower mouth.
A. For feeding air - Wind regulating disc is included under normal
situation.
B. For inhaling air - CX-3 and CX-5 can be installed a muffler if
necessary. |
| Inspection |
| When you receive the blower, please check
following items ? |
| 1. |
Do the contents on the label conform to what
you order ?for example, voltage, hertz and power (KW). |
| 2. |
Are there any damages during the
transportation. |
| INSTALLATION |
| (1) Installation Site |
| Ambient Temperature and humidity should meet
the following conditions: |
| ■ |
Single phase - 5 ~ 40°C |
| ■ |
There phase - 10 ~ 40°C |
| ■ |
Select site with good ventilation and less
dust and humidity. |
| ■ |
Please use umbrella when installation is
made on an open space. |
| (2) Methods of Installation: |
| 1. |
Secure the installation with screw on
leveling and hard foundation or base. Standard basic weight is generally
about 3 times of blower. If the base is uneven, the blower stand may be
deformed during fixing of screw. It is therefore that special attention
should be made to install additional vibration control unit to reduce
its noise. |
| 2. |
Blower is normally designed to make bearing
on axial leveling position. When suction inlet is upward or downward
during application, the weight of impeller and rotor shaft are added on
one side bearing to enlarge over load and thus reducing life of bearing.
Please contact our business department first when vertical site is used. |
| WIRING |
| 1. |
The system rated voltage and frequency The
record value same as those indicated on the rating plate. |
| 2. |
Voltage variance should be kept within +5%
of a rated voltage, +10% is sometime used, but it is better not to use
as its voltage is too big and is liable to be broken down. |
| 3. |
Due to blower has no over load heat
protection fixture, it is unable to control heat. Therefore, please
install overload protective magnetic switch of same horsepower and safe
current is adjusted below same value of nameplate. |
| 4. |
Select enough thickness of electric wire
according to horse power of motor and electric working methods in
accordance with European Union Safety information can be obtained from
such as: EN60204-1 ; EN60034 ; EN292 ; EN294 ; IEE Wiring regulations
Particular industries and countries have further safety requirements.
Refer to their trade & safety bodies. |
| 5. |
Check direction of rotation .Turn on the
switch for a while (twinkling) after completion of line connecting t
check its rotation direction and noiseless. The arrow on blower
indicates rotation direction. If rotation direction is wrong such as
turning into 3 phase, just replace any 2 lines of 3 electric wires. |
| 6. |
Grounding . Please install earth lines to
prevent from electric leakage accident. |
| OPERATION |
| 1.Part of blower |
| |
(1) Overload will be happened when it is
completely opened. |
| |
(2) Avoid turn switch on and off repeatedly
within one minute so as leading overheat of motor. |
| 2.Control on frequency changer |
| |
When frequency changer is used, power supply
ripple is distorted, motor noise is loud , and vibration is big too.When
using frequency changer for ooperation if leading to rise of temperature
or vibration, please stop operation. |
| Please use it under following terms and
conditions. |
| |
(1) |
Maximum frequency (RPM) Must be kept within frequency as
indicated and within rated amperage. |
| |
(2) |
Minimum frequency (RPM) Must be kept over 30 Hz, and
within a rated amperage |
| |
(3) |
A single-phase motor can not be used to operate a
frequency changer. |